Propose a change

The Heat Network (Metering and Billing) Regulations 2014

Write the words of this act the way you think they should read. Solon shows your change as a redline against the published text and pins it to that exact text, so it can never be applied to wording you did not see.

Change 1

What to do with it
As published

SCHEDULE 1 Analysis of cost effectiveness and technical feasibility

Regulations 3, 4 and 6 1 (1) Where sub-paragraph (2) applies it will be considered cost effective for the purposes of regulations 4(6) and 6(4) for the heat supplier to install meters in a building in accordance with regulations 4(3) to (4) and 6(2). (2) This sub-paragraph applies where the net present value of projected energy savings to all the final customers in the building supplied with heating, cooling or hot water by the heat supplier, over the 10 year period subsequent to installation, is greater than the net present value of the estimated reasonable costs of installing the meters in that building. 2 The matters to be taken into account in estimating the costs of installation are the capital, installation, operation and maintenance costs of the meters, taking into account— (a) the building type, age and number of individual private dwellings or non-domestic premises in the building; (b) the number of storeys in the building; (c) the geographical location of the building; (d) in the case of a building not containing private dwellings, the type of use of the building; (e) whether the costs could be reduced if another building supplied from the same district heat network is also to have meters installed in accordance with these regulations; (f) any costs of access to private dwelling or non-domestic premises including legal costs; (g) any costs of access to or isolation of pipework; (h) any costs of repair to decoration or building fabric as a consequence of the installation; (i) any costs of installation of temperature control devices; (j) the cost of equipment and software to collect data from the meters to be used for billing; (k) the cost of issuing bills and billing information; and (l) the cost of re-calibrating the meters periodically to ensure accuracy of performance. 3 The projected energy savings over the 10 year period subsequent to installation for the purpose of paragraph 1 is— (a) 20% of the heat or cooling demand in the case of a building consisting mainly of private dwellings, except for the one year period subsequent to installation when the projected value to be applied is 10% of the heat or cooling demand; and (b) 10% of the heat or cooling demand in the case of any other building except for the one year period subsequent to installation where the projected value to be applied is 5% of the heat or cooling demand. 4 It will be considered technically feasible to install meters in a building consisting mainly of private dwellings unless— (a) there is more than one entry point for the pipes of the district heat network or communal heating into each private dwelling within that building or the entry point for the pipes is unknown; or (b) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 It will be considered technically feasible to install meters in a building not consisting mainly of private dwellings unless— (a) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (b) there is more than one entry point for the pipes of the district heat network heating or communal heating into each private dwelling or non-domestic premises in a building or the entry point of the pipes is unknown; or (c) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 (1) Where sub-paragraph (2) applies it will be considered cost effective for the purpose of regulation 6(4) to install heat cost allocators and thermostatic radiator valves in accordance with regulation 6(2). (2) This sub-paragraph applies where the net present value of the projected energy savings to the final customers in the building over the 10 year period subsequent to installation is greater than the net present value of the estimated reasonable costs of installing hot water meters in the building and a heat cost allocator and thermostatic radiator valve for every radiator in that building. 7 The matters to be taken into account in estimating the costs of installation of heat cost allocators and thermostatic radiator valves are the capital, installation, operation and maintenance costs of the heat cost allocators and thermostatic radiator valves taking into account— (a) any cost of access to private dwelling or non-domestic premises including legal costs; (b) the cost of equipment and software to collect data from the heat cost allocators to be used for billing; (c) the cost of re-calibrating the heat cost allocators periodically to ensure accuracy of performance; ... (d) the cost of issuing bills and billing information; (e) the matters mentioned in paragraph 2(a) to (d); and (f) whether the costs could be reduced if another building supplied from the same district heat network is also to have heat cost allocators and thermostatic radiator valves installed in accordance with regulation 6(2). 8 The projected energy savings over the 10 year period subsequent to installation for the purpose of paragraph 6 is— (a) 20% of the heat or cooling demand in the case of a building consisting mainly of private dwellings, except for the one year period subsequent to installation when the projected value to be applied is 10% of the heat or cooling demand; and (b) 10% of the heat or cooling demand in the case of any other building except for the one year period subsequent to installation when the projected value to be applied is 5% of the heat or cooling demand. 9 For the purpose of this Schedule, the one year period and 10 year period subsequent to installation begin the day after completion of the installation of— (a) all the meters and temperature control devices in a building, or (b) all the heat cost allocators, thermostatic radiator valves and hot water meters in a building. 10 In this Schedule, “heat or cooling demand” for a building means the actual heat or cooling consumption for the building or an estimated heat or cooling demand for the building calculated using industry standard methodologies and assumptions for calculating heat demand, taking into account— (a) the construction, fabric, ventilation and age of the building; (b) the number of individual private dwellings or non-domestic premises in the building; (c) the number of storeys in the building; (d) the geographical location of the building; (e) the type of use of the building; (f) heat and cooling plant and system efficiency. 11 A real discount rate of 3.5% is to be applied to calculate net present value under this Schedule.

Your change, as a redline

SCHEDULE 1 Analysis of cost effectiveness and technical feasibility

Regulations 3, 4 and 6 1 (1) Where sub-paragraph (2) applies it will be considered cost effective for the purposes of regulations 4(6) and 6(4) for the heat supplier to install meters in a building in accordance with regulations 4(3) to (4) and 6(2). (2) This sub-paragraph applies where the net present value of projected energy savings to all the final customers in the building supplied with heating, cooling or hot water by the heat supplier, over the 10 year period subsequent to installation, is greater than the net present value of the estimated reasonable costs of installing the meters in that building. 2 The matters to be taken into account in estimating the costs of installation are the capital, installation, operation and maintenance costs of the meters, taking into account— (a) the building type, age and number of individual private dwellings or non-domestic premises in the building; (b) the number of storeys in the building; (c) the geographical location of the building; (d) in the case of a building not containing private dwellings, the type of use of the building; (e) whether the costs could be reduced if another building supplied from the same district heat network is also to have meters installed in accordance with these regulations; (f) any costs of access to private dwelling or non-domestic premises including legal costs; (g) any costs of access to or isolation of pipework; (h) any costs of repair to decoration or building fabric as a consequence of the installation; (i) any costs of installation of temperature control devices; (j) the cost of equipment and software to collect data from the meters to be used for billing; (k) the cost of issuing bills and billing information; and (l) the cost of re-calibrating the meters periodically to ensure accuracy of performance. 3 The projected energy savings over the 10 year period subsequent to installation for the purpose of paragraph 1 is— (a) 20% of the heat or cooling demand in the case of a building consisting mainly of private dwellings, except for the one year period subsequent to installation when the projected value to be applied is 10% of the heat or cooling demand; and (b) 10% of the heat or cooling demand in the case of any other building except for the one year period subsequent to installation where the projected value to be applied is 5% of the heat or cooling demand. 4 It will be considered technically feasible to install meters in a building consisting mainly of private dwellings unless— (a) there is more than one entry point for the pipes of the district heat network or communal heating into each private dwelling within that building or the entry point for the pipes is unknown; or (b) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 It will be considered technically feasible to install meters in a building not consisting mainly of private dwellings unless— (a) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (b) there is more than one entry point for the pipes of the district heat network heating or communal heating into each private dwelling or non-domestic premises in a building or the entry point of the pipes is unknown; or (c) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 (1) Where sub-paragraph (2) applies it will be considered cost effective for the purpose of regulation 6(4) to install heat cost allocators and thermostatic radiator valves in accordance with regulation 6(2). (2) This sub-paragraph applies where the net present value of the projected energy savings to the final customers in the building over the 10 year period subsequent to installation is greater than the net present value of the estimated reasonable costs of installing hot water meters in the building and a heat cost allocator and thermostatic radiator valve for every radiator in that building. 7 The matters to be taken into account in estimating the costs of installation of heat cost allocators and thermostatic radiator valves are the capital, installation, operation and maintenance costs of the heat cost allocators and thermostatic radiator valves taking into account— (a) any cost of access to private dwelling or non-domestic premises including legal costs; (b) the cost of equipment and software to collect data from the heat cost allocators to be used for billing; (c) the cost of re-calibrating the heat cost allocators periodically to ensure accuracy of performance; ... (d) the cost of issuing bills and billing information; (e) the matters mentioned in paragraph 2(a) to (d); and (f) whether the costs could be reduced if another building supplied from the same district heat network is also to have heat cost allocators and thermostatic radiator valves installed in accordance with regulation 6(2). 8 The projected energy savings over the 10 year period subsequent to installation for the purpose of paragraph 6 is— (a) 20% of the heat or cooling demand in the case of a building consisting mainly of private dwellings, except for the one year period subsequent to installation when the projected value to be applied is 10% of the heat or cooling demand; and (b) 10% of the heat or cooling demand in the case of any other building except for the one year period subsequent to installation when the projected value to be applied is 5% of the heat or cooling demand. 9 For the purpose of this Schedule, the one year period and 10 year period subsequent to installation begin the day after completion of the installation of— (a) all the meters and temperature control devices in a building, or (b) all the heat cost allocators, thermostatic radiator valves and hot water meters in a building. 10 In this Schedule, “heat or cooling demand” for a building means the actual heat or cooling consumption for the building or an estimated heat or cooling demand for the building calculated using industry standard methodologies and assumptions for calculating heat demand, taking into account— (a) the construction, fabric, ventilation and age of the building; (b) the number of individual private dwellings or non-domestic premises in the building; (c) the number of storeys in the building; (d) the geographical location of the building; (e) the type of use of the building; (f) heat and cooling plant and system efficiency. 11 A real discount rate of 3.5% is to be applied to calculate net present value under this Schedule.

One line that says what changes, such as "Halve the dog tax".

Who it helps, what it costs, what it fixes. It is what persuades people to support it.

How this law is officially changed

Solon does not know this law's official route yet. The proposal is recorded all the same, and the route appears here once its source is added.

A proposal here is not law. Support on Solon is evidence that people want the change; the official route says what it takes to make it law.

Sign in to file your proposal. What you have written stays on this page.

Sign in to file it

Think it through

Ask what your change would do, who would gain and who would bear a cost, and where something like it is already law. The assistant reads your draft as it stands, cites the law and the studies it finds, and takes no side. What you file stays yours.

Questions to start with
Think it through
Legal information from the published text, not advice for your case. Check the sources. Find a law · What the register holds