SCHEDULE 14 MAXIMUM AND MINIMUM DESIGN PARAMETERS

Article 3 Table 11 (1) Element of authorised development | (2) Work No. | (3) Maximum length (metres) | (4) Maximum width (metres) | (5) Maximum height (metres) (above finished floor level of 3.0m AOD) | (6) Minimum height (metres) (above finished floor level of 3.0m AOD) Gatehouse / weighbridge | 2A | 9.5 | 2.4 | 3 Tipping hall | 1 | 58.5 | 38 | 18.5 Fire water tank | 2A | 16 | 10 Fire water pump building | 2A | 12.5 | 9.5 | 5.5 Waste bunker building | 1 | 102 | 37 | 38.5 Tipping bunker | 1 | – | – | -14 Main waste bunker | 1 | – | – | -14 Boiler house building | 1 | 55 | 47.6 | 52 Loading area (a) | 1 | 12.2 | 12.2 | 12 APCr silos | 1 | 33.3 | 12.2 | 37 Loading area (b) | 1 | 12.2 | 12.2 | 12 Air pollution control building | 1 | 33.2 | 28.6 | 37 Induced draft fans building | 1 | 10 | 10 | 12 Chimneys | 1A | – | 3.2 | 90 | 84 CEMS platform | 1A | – | – | 18 Switchgear building north | 1 | 35.2 | 10 | 35 Switchgear building south | 1 | 12.4 | 10 | 18 IBA enclosure east | 1 | 14 | 11 | 12 IBA enclosure west | 1 | 11 | 6 | 12 Diesel tanks and urea tanks building | 1 | 25.9 | 9.1 | 35 Compressed air station | 1 | 13 | 8 | 10 Main transformer | 2A | 11 | 6 | 12 Emergency diesel generator | 1 | 13.5 | 5.5 | 12 Air cooled condenser | 1 | 37 | 37 | 30 Turbine hall | 1 | 47 | 34 | 27 Water treatment plant | 1 | 30 | 22 | 18 Workshop and stores | 2A | 34 | 15 | 18 Administration building | 1B | 34 | 12 | 15 132kV switching compound | 2A | 23 | 13 | 6.5 Private wire transformer | 2A | 11 | 5 | 12 Private wire switchgear compound | 2A | 7 | 6 | 12 Water re–cooling system | 1 | 18.5 | 7.5 | 27 Steam and condensate pipelines | 3 | – | – | 23

Your change, as a redline

SCHEDULE 14 MAXIMUM AND MINIMUM DESIGN PARAMETERS

Article 3 Table 11 (1) Element of authorised development | (2) Work No. | (3) Maximum length (metres) | (4) Maximum width (metres) | (5) Maximum height (metres) (above finished floor level of 3.0m AOD) | (6) Minimum height (metres) (above finished floor level of 3.0m AOD) Gatehouse / weighbridge | 2A | 9.5 | 2.4 | 3 Tipping hall | 1 | 58.5 | 38 | 18.5 Fire water tank | 2A | 16 | 10 Fire water pump building | 2A | 12.5 | 9.5 | 5.5 Waste bunker building | 1 | 102 | 37 | 38.5 Tipping bunker | 1 | – | – | -14 Main waste bunker | 1 | – | – | -14 Boiler house building | 1 | 55 | 47.6 | 52 Loading area (a) | 1 | 12.2 | 12.2 | 12 APCr silos | 1 | 33.3 | 12.2 | 37 Loading area (b) | 1 | 12.2 | 12.2 | 12 Air pollution control building | 1 | 33.2 | 28.6 | 37 Induced draft fans building | 1 | 10 | 10 | 12 Chimneys | 1A | – | 3.2 | 90 | 84 CEMS platform | 1A | – | – | 18 Switchgear building north | 1 | 35.2 | 10 | 35 Switchgear building south | 1 | 12.4 | 10 | 18 IBA enclosure east | 1 | 14 | 11 | 12 IBA enclosure west | 1 | 11 | 6 | 12 Diesel tanks and urea tanks building | 1 | 25.9 | 9.1 | 35 Compressed air station | 1 | 13 | 8 | 10 Main transformer | 2A | 11 | 6 | 12 Emergency diesel generator | 1 | 13.5 | 5.5 | 12 Air cooled condenser | 1 | 37 | 37 | 30 Turbine hall | 1 | 47 | 34 | 27 Water treatment plant | 1 | 30 | 22 | 18 Workshop and stores | 2A | 34 | 15 | 18 Administration building | 1B | 34 | 12 | 15 132kV switching compound | 2A | 23 | 13 | 6.5 Private wire transformer | 2A | 11 | 5 | 12 Private wire switchgear compound | 2A | 7 | 6 | 12 Water re–cooling system | 1 | 18.5 | 7.5 | 27 Steam and condensate pipelines | 3 | – | – | 23

One line that says what changes, such as "Halve the dog tax".

Who it helps, what it costs, what it fixes. It is what persuades people to support it.

How this law is officially changed

Solon does not know this law's official route yet. The proposal is recorded all the same, and the route appears here once its source is added.

A proposal here is not law. Support on Solon is evidence that people want the change; the official route says what it takes to make it law.

Sign in to file your proposal. What you have written stays on this page.

Sign in to file it

Think it through

Ask what your change would do, who would gain and who would bear a cost, and where something like it is already law. The assistant reads your draft as it stands, cites the law and the studies it finds, and takes no side. What you file stays yours.

Questions to start with
Think it through
Legal information from the published text, not advice for your case. Check the sources. Find a law · What the register holds